250V
[FA-] MPY-S, MPYC-S, MPYCY-S
Standards
JISC 3410-1999
IEC 60332-1
IEC 60332-3 Cat.A(for FA-type)
Cable Construction
Conductor |
M |
Tinned annealed stranded copper, class 2 according to IEC 60228 |
Insulation |
P |
85°C EPR as per JIS C 3401 |
Cabling |
|
Insulated conductors shall be cabled. |
Individual shield |
-S |
Tinned copper wire braid |
Bedding |
Y |
PVC as per JIS C 3401 |
Armor |
C |
Galvanized steel wire braid |
Sheath |
Y |
PVC as per JIS C 3401 |
Core identification |
|
Black No. on white insulation |
Outer sheath color |
|
Black |
Cable Parameter
250V (FA-) MPY-S
No. of cores |
Conductor | Thick. of insulation |
Dia. of shield wire |
Thick. of bedding |
(FA-) MPY-S | ||||
Size | Construction | O.D | Nom. overall dia |
Tolerance | Cable Weight |
||||
mm² | No./mm | mm | mm | mm | mm | mm | mm | kg/km | |
2 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.1 |
9.9 |
0.4 |
150 |
4 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.2 |
11.6 |
0.5 |
230 |
7 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.3 |
13.9 |
0.6 |
350 |
12 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.4 |
18.2 |
0.8 |
570 |
19 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.5 |
21.5 |
0.9 |
840 |
27 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.7 |
26 |
1.1 |
1200 |
37 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.8 |
29.2 |
1.2 |
1600 |
44 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
2 |
33.2 |
1.4 |
2000 |
250V (FA-) MPYC-S
No. of cores | Conductor | Thick. of insulation | Dia. of shield wire | Thick. of bedding | Dia. of steel wire | (FA-) MPYC-S | ||||
Size | Construction | O.D | Nom.overall dia | Tolerance | Cable Weight | |||||
mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | kg/km | |
2 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.1 | 0.3 | 11.2 | 0.4 | 210 |
4 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.2 | 0.3 | 12.9 | 0.5 | 300 |
7 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.3 | 0.3 | 15.2 | 0.6 | 435 |
12 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.4 | 0.3 | 19.5 | 0.8 | 685 |
19 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.5 | 0.3 | 22.8 | 0.9 | 980 |
27 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.7 | 0.3 | 27.3 | 1.1 | 1360 |
37 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.8 | 0.3 | 30.5 | 1.2 | 1760 |
44 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 2 | 0.4 | 35 | 1.4 | 2240 |
250V (FA-) MPYCY-S
No. of cores |
Conductor | Thick. of insulation |
Dia. of shield wire |
Thick. of bedding |
Dia. of steel wire |
Thick. of covering |
(FA-) MPYCY-S | ||||
Size | Construction | O.D | Nom. overall dia |
Tolerance | Cable Weight |
||||||
mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | |
2 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.1 |
0.3 |
0.9 |
13.2 |
0.5 |
260 |
4 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.2 |
0.3 |
0.9 |
14.9 |
0.6 |
360 |
7 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.3 |
0.3 |
1 |
17.4 |
0.7 |
515 |
12 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.4 |
0.3 |
1.1 |
21.9 |
0.9 |
795 |
19 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.5 |
0.3 |
1.2 |
25.4 |
1 |
1120 |
27 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.7 |
0.3 |
1.3 |
30.1 |
1.2 |
1540 |
37 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.8 |
0.3 |
1.4 |
33.5 |
1.3 |
1970 |
44 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
2 |
0.4 |
1.5 |
38.4 |
1.5 |
2500 |